Trampoline Park Netting: The Test Is Half an Adult Jump
The test a barrier panel has to survive is written down, and it is smaller than the job. A 90 kg bag is suspended from a pivot 3.0 m above the centre of the panel, lifted through 30 degrees and released. It arrives at 2.81 m per second and delivers 355 joules. Then it is done again.
A 70 kg adult who rebounds one metre off a trampoline bed leaves the bed at 4.43 m per second. That is 687 joules. One ordinary bounce by one adult carries 1.9 times the energy of the certification impact, and a panel on a public court is asked to absorb that energy far more than twice.
None of this makes the test wrong. It makes it a check on material and attachment, not a calculation of capacity. The distance between those two numbers is where netting decisions actually happen, and most of them are made on a purchase order long before anyone reads a clause.
This article follows those decisions in the order they arrive: what the net has to stop, what mesh and twine change, where the load goes after the fabric, how much room the deflection needs, what the building does to the fibre, and how to decide when to replace it. Where the documents disagree, we say so. Where no document answers, we say that too.
Where the numbers came from: the pendulum figures are Appendix E of the Australian Trampoline Parks Association Code of Practice (Rev 1406). The jump figures are our arithmetic: a rebound of height h gives impact energy mgh for mass m, so a 70 kg adult rising 1.0 m arrives with 70 x 9.81 x 1.0 = 687 joules at 4.43 m/s. Both assume all of the energy goes into the net, with no air drag and no energy lost to the bed. Real impacts are slightly softer and much more uneven.
1. What the panel test actually applies
The pendulum is the only place in the trampoline documents where a net is struck by a known mass at a known speed. That makes it the closest thing the industry has to a physics benchmark, so it is worth reading exactly what it does and does not do.
| Impact case | Mass | Approach speed | Energy | Share of test |
|---|---|---|---|---|
| Pendulum test, 30 degrees from a 3.0 m pivot | 90 kg | 2.81 m/s | 355 J | 1.00 |
| Adult rebound of 0.35 m, soft bounce | 70 kg | 2.62 m/s | 240 J | 0.68 |
| Adult rebound of 0.50 m, routine bounce | 70 kg | 3.13 m/s | 343 J | 0.97 |
| Adult bounce of 1.00 m | 70 kg | 4.43 m/s | 687 J | 1.94 |
| Adult bounce of 1.50 m | 70 kg | 5.42 m/s | 1,030 J | 2.90 |
The first row is the test. The third row is what a normal bounce produces, and it sits inside the test figure. The fourth row is where a fit adult lives, at roughly double. Read the table as a scale, not a pass mark: the certificate tells you the fabric and the fixings survived one known hit twice, at the centre of one panel, at the energy of a half-metre bounce.
Two details matter more than the number. The bag is aimed at the centre, where a panel has the most fabric and the least hardware. And there are exactly two impacts. Panels fail at edges, at borders and at ties, and they fail after repetition rather than on the first hit.
The pendulum is also not universal. It belongs to one national code. ASTM F2375 handles netting for amusement devices through material tests, prototype hole-size tests and an in-place test of the installed barrier, and ISO 23659 delegates component requirements rather than restating them. If a supplier offers a single sentence about passing a net standard, the useful question is which document, which clause and which test body.
2. A net has three jobs, and only one is containment
Buyers ask for a safety net. The documents do not have that product. They have barrier netting, no-hold netting, climb netting, safety netting and debris netting, and the list exists because each one is asked to do something different to a body.
Job one: keep patrons inside ASTM F2970 requires a patron containment system around the perimeter of a court or a court foam pit, with the wall height measured from the horizontal frame. Straightforward, and it is the only job most buyers think about.
Job two: keep bodies off hard things The same standard requires the barrier to be installed so that patrons cannot contact unprotected obstructions, suspension systems, frame components, unprotected surfaces or the floor when the highest anticipated live load is applied. That is not a containment requirement. It is a stiffness requirement, and it is the one that turns impact energy into tie loads.
Job three: catch what falls through Under horizontal beds and behind angled beds, the Australian code asks for a barrier as a redundant fall barrier, unless a documented risk assessment shows an alternative that is as safe. Nets also guide patrons out of a trampoline into a foam pit, where the panel starts at the pit edge and runs back along the exiting bed.
Three jobs, three load cases, three products. A debris net that satisfies job one will not satisfy job two, because it is specified for holding rubbish, not for absorbing a body at 4 m/s. This is why the phrase high strength safety net on a quotation tells you nothing: it names a shopping category, not a performance.
3. Mesh decides which failure you get
Containment netting fails in two ways, and they are fixed by different changes. A body part passes through the aperture and is then held by it, which is a function of mesh size and node type. Or a strand breaks, which is a function of twine, knot abrasion and load path. Buying a heavier twine does nothing for the first failure, and buying a smaller aperture does nothing for the second.
| What you see | What caused it | What actually fixes it |
|---|---|---|
| Limb or head caught in the mesh | Aperture too wide for the smallest user, or a knot that grips | Smaller aperture in a no-hold construction, checked against the smallest age band the venue admits |
| Strands broken mid-panel | Twine too light for the impact energy, or abrasion at a hard node | Heavier twine and a knotless construction, plus removal of the hard node |
| Border rope pulled out of the edge | Finishing at the border and tie spacing, not the fabric | Bound or taped edge with a rated border rope, tied at the spacing the post grid can carry |
| Panel sagging between posts | Pre-tension lost, or ties creeping | Re-tension to the manufacturer setting and check the ties at every inspection |
Knotless Raschel fabric costs more per square metre and is harder to repair. Knotted fabric is cheaper, easier to patch, and concentrates stress at every knot. Neither is wrong. The choice belongs to the duty: a panel that takes repeated body impacts from children of mixed size wants the smoother surface, and a panel that separates zones wants the cheaper one.
There is a third variable that indoor venues rarely consider: open area. A tighter mesh blocks more air and more sightline. On a court where staff supervision depends on seeing through the wall, a mesh chosen only for strength can make the venue harder to run. The specification should say what the net must let through as well as what it must stop. Material and finish testing is covered on the materials and quality page.
4. The panel passes; the ties have to hold
Load leaves the fabric through the border, then through ties or sleeves, then into posts or building steel. Each step multiplies uncertainty, and the test never visits the end of the chain.
Take a 1,200 m² court, roughly 30 m by 40 m, which is about 12,900 sq ft. The perimeter is 140 m. With containment 4 m high, that is 560 m² of net, or about 47% of the floor area. Ties at 3 m centres give 47 posts and 47 bays of about 12 m² each.
Now put the 687 joule impact into one bay, 0.5 m from a post. If the net deflects 0.25 m, the average force over that travel is 687 divided by 0.25, or 2.7 kN. Peak force on a net is roughly twice the average, so plan on about 5.5 kN. That is eight times the weight of the person who produced it, arriving at two ties, in a fraction of a second.
Design values like that are normal at the frame, and they are not normal at a building fixing. A tie into a ceiling hook plate, a purlin or a thin topping slab is a different structure from a post cast into the floor, which is why the fixing schedule and the net schedule have to be written by the same person. The failure mode this creates has been seen on this site before, in the case of 29 ceiling hook plates that failed, and the frame side of the same load path is covered in the article on floor load and slab capacity.
A net that is too tight has no deflection left and sends the whole impact into the ties as shock. A net that is too slack lets the patron reach the surface it was supposed to protect. The useful specification gives a tension setting and a tie spacing, and asks the installer to record both at handover.
5. Deflection needs somewhere to go
Every joule has to be absorbed over a distance. Halve the distance and you double the force. At 0.10 m of deflection, the same 687 joule impact averages 6.9 kN and peaks near 14 kN, which is enough to make a marginal fixing the weakest item in the room.
That is why the clearance behind and above a net is a design number, not a tolerance. ASTM F2970 asks that netting be installed to prevent direct contact with obstructions above, behind or adjacent to the court, and that any obstruction which can still be reached under force be protected with impact attenuating material. In practice that means the net needs 250 mm to 400 mm of clear travel, and the building has to give it up.
The competition for that space is predictable. Ducts, light fittings, sprinkler pipe, structure and the net all want the same void above the court, and the net is usually the last trade to arrive. The result is a net that is either pulled tight against a duct or padded around it, and both outcomes cost money after the fact. Clear height is decided long before this point, which is the argument in the article on ceiling height, and the layout arithmetic sits in the 22,000 sq ft layout breakdown.
Get this wrong and the cost is not the net. It is re-routing services, adding a padded obstruction into a sightline, or accepting a court that is 300 mm narrower than the drawing. All three are cheaper to decide at design stage than to find at commissioning.
6. Indoors is not the same as out of the sun
Both major codes treat fire and sunlight as separate questions, and they attach each one to a condition about location. Inside an enclosed structure, netting must be flame resistant. Where netting is used outdoors and subject to UV degradation, it must be protected from UV or include UV inhibitors, and the supplier must certify that a representative sample was tested.
Read those two conditions together and a gap appears. A venue with a glazed roof, roof lights or a fully glazed mall facade puts sunlight on an indoor net, and neither condition names it. The flame certificate covers the fire question. Nothing covers the sunlight question, because the test is triggered by the word outdoor rather than by the exposure.
ISO 23659 will not close the gap either. It excludes the chemical composition of components from its scope, so the standard that governs trampoline parks as a whole deliberately says nothing about what the yarn is made of.
The practical consequence is a question for the mill, not for the installer: which of the two properties was this yarn formulated and tested for, and can we see both reports. Flame retardants and light stabilisers are separate additive systems, tested separately, and a pass in one test says nothing about the other. A net that carries a fire certificate and no UV data is the normal case for indoor supply, and it is the wrong case under a glass roof.
The cost of missing it does not appear at handover. It appears in year three, in the sunniest bay, as a border that starts to fail under load it used to carry.
7. Replacement is a cycle you have to measure
No trampoline document sets a replacement interval for netting. The codes ask for visual inspection, for a list of safety critical components, and for a documented replacement policy. They do not give a number of years, because the number depends on exposure, usage and the fibre, and nobody has published the field data.
What does exist is textile data from adjacent industries. A nonwoven polypropylene geotextile lost roughly 30% of its tensile strength after 24 months of outdoor exposure in a peer-reviewed field and laboratory study published in Materials in 2022. The polymer family is the same, and the mechanism is the same chain scission under ultraviolet light. The number is not a net number, and we are not presenting it as one. It is an order of magnitude for a polyolefin textile left in the sun.
Indoor parks are not outdoors, which is exactly the problem: the exposure is unknown, so the interval is unknown. The honest method is to measure rather than guess. Keep a one square metre offcut from every net run, labelled with the installation date, stored dark and dry. Test it at year three and year five against a new sample.
The method for that test is already written. Appendix F of the ATPA code specifies xenon arc exposure with a defined irradiance and a total energy dose, which corresponds to roughly 500 hours in the apparatus, followed by tensile testing of exposed and control samples. Whether or not that code governs your market, it gives you a defensible way to answer a question every operator eventually asks.
8. The paperwork to collect before the container ships
The strongest part of the Australian code is not a dimension. It is the list of certificates the supplier has to hand over before shipment, and it reads like a specification for the buyer rather than for the manufacturer.
- Certification that the netting meets the code.
- Certification of flame retardation for netting used inside enclosed structures.
- Certification that it was installed to the manufacturer specification.
- Certification of UV inhibitors and a tested sample, where the netting is outdoors.
- Certification of lead content in the material.
Alongside those, the code asks for a statement of compliance prepared by a competent person before opening and then annually, displayed where the public can see it, carrying the date of manufacture, the standards the design complies with, and the dates of the last and next inspection. Whether your jurisdiction requires that document or not, it is the right shape for the file.
A netting specification should also carry the fields that make a replacement order possible without a site visit: construction type, yarn, mesh aperture, break strength in warp and fill, burst strength, weight per square metre, border rope, flame treatment and UV stabiliser. The ATPA code goes further and asks that the product description be complete enough to eliminate errors in its replacement. That is a good test of any quotation. If the description would not let a second supplier make the same panel, it is not a description. The installation sequence for these items is covered in the module and freight article, and the certification scope in general on the safety standards page.
9. The judgment table
Netting decisions reduce to a small number of conditions. Read the left column first, then take the action in the right column before the purchase order is signed.
| If the venue is like this | Then specify this |
|---|---|
| Ground floor court, solid roof, no glazing above the nets | Barrier netting at the containment height your market requires, flame certificate, tie spacing matched to the post grid |
| Glazed roof, roof lights or a glazed facade over the court | UV stabilised yarn as well as flame retardant, a tested UV sample, and a retained offcut for re-testing at year three |
| Net hung from building steel rather than posts | Fixing design by the same engineer as the frame, with the peak tie load stated, not an off-the-shelf hook plate |
| Net used as a pit guide or a redundant barrier under beds | A separate line item and a separate product; do not let it be absorbed into the perimeter net price |
| Second-hand panels or a net moved from another site | Do not use them. Strength history and exposure are unknown, and no certificate survives a re-installation |
| Angled beds, performance walls or a court next to the party rooms | Net and frame designed together, with the deflection travel shown on the drawing |
Two conditions are still open, and we are not going to close them with a number. How fast an indoor net loses strength depends on a dose nobody measures at most venues. And how much energy a panel should be designed for depends on the oldest and heaviest patron a venue admits, which is an operating policy, not a product property.
10. Three Things You Can Do Today
1. Ask for the clause, not the certificate. Any supplier can say the net meets the standard. Ask for the document, the edition and the test body, then check whether the test covers attachment as well as fabric. The design to delivery process is the place to put that request in writing.
2. Measure the deflection travel on the drawing. Mark 250 mm to 400 mm behind every net line and see what is already there. If a duct or a light fitting is inside that band, decide now rather than at commissioning.
3. Start the replacement file on day one. Cut a labelled offcut from each net run, store it dark, and put a review date in the maintenance calendar for year three. It is the only way to replace a net on evidence instead of on appearance.
Netting is one of the few items where a wrong line on the quotation is invisible for three years and then expensive for a month. If you want a second opinion on a net and frame schedule before you commit, our team reviews them against the market you are building in.
Related equipment and accessories are listed under trampoline park accessories.
FAQ
How tall does trampoline park netting need to be?
It is set by the standard your market pins, and the height is measured from the horizontal trampoline frame rather than from the floor. ASTM, ISO and the Australian code do not use the same figure. Ask the installer which document and which edition the design is built to, and get that sentence in the handover file. A number copied from a blog is not a substitute.
How often should trampoline park netting be replaced?
No document sets an interval. The codes require visual inspection and a documented replacement policy, which puts the decision on the operator. The defensible method is to retain a sample at installation and test it at year three, then at year five, so the decision rests on measured strength loss rather than on how the net looks.
What mesh size should containment netting have?
There is no single answer, because the aperture depends on what the panel is for. Containment, no-hold netting and debris netting are specified differently, and the smallest age band the venue admits sets the constraint. Treat aperture and twine weight as a pair rather than choosing one in isolation.
Can a damaged net be repaired instead of replaced?
Patching is contemplated by the codes, provided the repair method and materials come from the manufacturer and the work is recorded. A patch restores containment locally. It does not restore the strength of the surrounding panel, which is why a repaired net still needs the sample test and the inspection record behind it.
Does indoor netting need a fire certificate?
Yes. Both ASTM F2970 and the Australian code require flame resistant material for netting inside an enclosed structure, and they name recognised test methods for it. UV protection is a separate requirement, triggered by outdoor exposure, so a venue with a glazed roof should ask for both and expect two reports.
Sources
- ASTM International, “F2970-22 Standard Practice for Design, Manufacture, Installation, Operation, Maintenance, Inspection and Major Modification of Trampoline Courts”, 2022 – astm.org/f2970-22.html
- ASTM International, “F2375-25 Standard Practice for Design, Manufacture, Installation and Testing of Climbing Nets and Netting/Mesh used in Amusement Rides, Devices, Play Areas and Attractions”, May 2025 – astm.org, F2375
- International Organization for Standardization, “ISO 23659:2022 Sports and recreational facilities, Trampoline parks, Safety requirements”, November 2022, confirmed 2024 – iso.org/standard/76556.html
- Australian Trampoline Parks Association, “Code of Practice for Design, Manufacture, Installation, Operation, Maintenance, Inspection and Structural or Major Modification of Trampoline Parks”, Rev 1406, 2014, clauses 3.2.3 and 3.5.1, Appendices E and F – atpa.org.au code of practice
- Materials (MDPI), “Weathering of a Nonwoven Polypropylene Geotextile: Field vs. Laboratory Exposure”, 18 November 2022 – mdpi.com/1996-1944/15/22/8216
- National Fire Protection Association, “NFPA 701, Standard Methods of Fire Tests for Flame Propagation of Textiles and Films” – nfpa.org, NFPA 701
- Turf Net Sports Supplies, “Trampoline Netting” fabric data sheet, construction, yarn and break strength fields – turfnetsportssupplies.com, trampoline netting